Temperature Testing

Professional temperature testing solutions designed to evaluate product durability, operational stability, and reliability under controlled high and low temperature conditions.

Climatic Test Chamber

ACS Walk in Chamber

Used for controlled low and high temperature testing to evaluate product reliability, operational stability, and material performance under simulated environmental conditions. Suitable for industrial, automotive, electronics, and component reliability testing.

Dimensions

  • Internal Space: 210 × 200 × 200 (WxDxH cm)
  • Temperature: -60°C ~ 90°C
  • Ramp Rate: 3 (°C/min)
  • Relative Humidity: 15 ~ 95 (%)
  • Power: 415VAC/50Hz, 120A, 3Ø

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Climats Chamber

CSZ Walk In Chamber

Designed for large-scale environmental simulation and temperature reliability testing. It provides precise control of extreme temperature conditions for evaluating product durability, performance stability, and long-term environmental resistance across industrial and electronic applications.

Dimensions

  • Internal Space: 215 x 210 x 215 (WxDxH cm)
  • Temperature: -60°C ~ 90°C
  • Ramp Rate: 3 (°C/min)
  • Relative Humidity: 15 ~ 95 (%)
  • Power: 415VAC/50Hz, 120A, 3Ø

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Environmental Chamber

Climats Temperature and Humidity Chamber

A precision environmental testing chamber designed to simulate controlled humidity and temperature conditions for reliability, durability, and material performance testing. Commonly used in laboratories and industrial applications to evaluate product resistance against moisture and varying environmental conditions.

Dimensions

  • Internal Space: 118 x 108 x108 (WxDxH cm)
  • Temperature: -30 ~ 120 (°C)
  • Ramp Rate: 3 (°C/min)
  • Relative Humidity: 30 ~ 95 (%)
  • Power: 380V/40A, 3Ø

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Climats Chamber

Tabai Humid Chamber

Designed for large-scale environmental simulation and temperature reliability testing. It provides precise control of extreme temperature conditions for evaluating product durability, performance stability, and long-term environmental resistance across industrial and electronic applications.

Dimensions

  • Model: PSL-2GM
  • Internal Space: 60 x 60 x 85 (WxDxH cm)
  • Temperature: -60 ~ 130 (°C)
  • Relative Humidity: 25 ~ 95 (%)
  • Air Cool System

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Environmental Chamber

Envirotronic FLX900

High-precision environmental testing system engineered to deliver accurate temperature and humidity simulation for product reliability evaluation. Designed for demanding laboratory and industrial applications, it provides stable and consistent environmental control to support performance, durability, and quality assurance testing under various climatic conditions.

Dimensions

  • Internal Space: 118 x 108 x108 (WxDxH cm)
  • Temperature: -35 ~ 130 (°C)
  • Ramp Rate: 3 (°C/min)
  • Relative Humidity: 25 ~ 95 (%)
  • Power: 380V/40A, 3Ø

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Climats Chamber

Combine chamber

A high-performance environmental test chamber designed for precise temperature and humidity simulation. Built for reliability testing and quality assurance, it offers stable control, durable construction, and consistent performance for laboratory and industrial applications.

Dimensions

  • Internal Space: 1880 x 1000 x 1110 (WxDxH mm)
  • Temperature: -35 ~ 120 (°C)
  • Relative Humidity: 25 ~ 95 (%)
  • Power: 380V/40A, 3Ø
  • Air Cool System

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

IEC 60068-2-14 (Test Na) · ISO 16750-4 (Clause 5.3.2)

Rapid Change of Temperature (-60°C to 200°C)

IEC 60068-2-14 (Test Nb) · ISO 16750-4 (Clause 5.3.1)

Change of Temperature with specific rate (-60 °C to 150 °C)

IEC 60068-2-30 (Test Db) · ISO 16750-4 (Clause 5.6)

Damp Heat, Cyclic Test (25 °C to 55 °C) (95% RH)

IEC 60068-2-78 (Test Cab) · ISO 16750-4 (Clause 5.7)

Damp Heat, Steady State Test (30°C to 40°C) (95% RH)

ASTM F 1980

Accelerated Aging of Sterile Barrier Systems and Medical Devices (20 to 80°C)

Environmental Chamber

Heraues Votsch Oven

High-precision environmental testing system engineered to deliver accurate temperature and humidity simulation for product reliability evaluation. Designed for demanding laboratory and industrial applications, it provides stable and consistent environmental control to support performance, durability, and quality assurance testing under various climatic conditions.

Dimensions

  • Model: 15050
  • Internal Space: 45 x 43 x 40 (WxDxH cm)
  • Temperature: +30 ~ +250 (°C)
  • Power: 230V, 50Hz

Test Standards

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

ISO 16750-4 Test B

Dry (+250°C max)

Climats Chamber

Oven Memmert UM500

A high-performance laboratory oven designed for precise and reliable temperature control, ideal for drying, heating, sterilization, and thermal testing applications. Built with a durable stainless steel chamber, it provides uniform heat distribution, consistent performance, and long-term operational reliability.

Dimensions

  • Model: UM500
  • Internal Space: 56 x 40 x 48 (WxDxH cm)
  • Temperature: 50 ~ 250 (°C)
  • Power: 230V, 50Hz

Test Standards

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

ISO 16750-4 Test B

Dry (+250°C max)

Environmental Chamber

Tenny Jr. Hot/Cold Chamber

A versatile environmental test chamber designed to simulate both high and low temperature conditions for product reliability and durability testing. It delivers stable temperature control, uniform airflow distribution, and dependable performance for various industrial and laboratory applications.

Dimensions

  • Internal Space: 40 x 28 x 30 (WxDxH cm)
  • Temperature: -52 ~ 27 (°C)
  • Power: 100V/18A, 50Hz

Test Standards

IEC 60068-2-1 (Test A) · ISO 16750-4 (Clause 5.1.1)

Low Temperature Tests (down to -60°C)

IEC 60068-2-2 (Test B) · ISO 16750-4 (Clause 5.1.2)

High Temperature Tests (up to +200°C)

Why Temperature Testing Matters

Environmental temperature exposure may affect electrical performance, material integrity, mechanical stability, and overall product lifespan. Temperature testing helps manufacturers ensure products remain safe, functional, and reliable throughout their operational lifecycle.

These evaluations also support product qualification, compliance verification, quality assurance, and customer confidence across global markets.